济南办公室装修中插座安装位置及注意事项

来源:https://www.saiyunzs.com 时间:2019-11-05 19:01:56

  关于插座在济南办公室装修中的安装位置及注意事项,希望能为您提供一些帮助或建议。

  As for the installation position and precautions of socket in Jinan Office decoration, I hope to provide some help or suggestions for you.
  虽然开关插座可能是一个大问题,它是重要的,因为它的权力和的含义。每个办公室装饰是必不可少的,除了那些开关插座,也很少到地面插座安装,这个套接字和套接字有点不同,这个套接字比其他安装更多的困难,安装应该注意什么,这是一个简单的介绍。
  While switching sockets can be a big problem, it's important because of its power and safety implications. Every office decoration is indispensable. Besides those switch sockets, there are few ground sockets installed. This socket is a little different from the socket. This socket is more difficult than other installations. What should be paid attention to in installation? This is a simple introduction.
济南办公室装修
  ,要先介绍地板插座安装地板插座,了解他们只安装地板插座是有帮助的,这种非凡的插座一般是低盒和盖两部分,其安装应分为两部分。确保管道和接地插座连接顺利。将接地插座低盒固定好,并与金属管连接,在进行真正的接地处理时,与安装必须与室内装饰协调一致。
  First of all, it is helpful to introduce the installation of floor socket first. It is helpful to know that they only install floor socket. This kind of special socket is generally composed of low box and cover. Its installation should be divided into two parts. Make sure that the pipe and grounding socket are connected smoothly. First of all, fix the low box of the grounding socket and connect it with the metal pipe. When conducting the real grounding treatment, the installation must be coordinated with the indoor decoration.
  钢底箱定位
  Positioning of steel bottom box
  根据正确的施工图确定插座的安装位置,采用金属管连接钢箱。并将经纬仪固定在周围的混凝土或水泥上固定,有时需要将经纬仪埋入同一排的钢底箱中进行对准定位。
  Determine the installation position of the socket according to the correct construction drawing, and connect the steel box with the metal pipe. And fix the theodolite on the surrounding concrete or cement. Sometimes, it is necessary to embed the theodolite in the steel bottom box of the same row for alignment and positioning.
  的嵌入深度
  Embedded depth of
  ,根据设计图纸选择合适厚度的预埋钢底箱进行预埋处理,根据地面结构。钢箱表面一般应保持在距地面3-5mm的深度,然后浇筑混凝土或水泥固定。
  First of all, according to the design drawings, select the appropriate thickness of embedded steel bottom box for embedded treatment, according to the ground structure. The surface of the steel box shall generally be kept at a depth of 3-5mm from the ground, and then concrete or cement shall be poured for fixation.
  钢底箱厚度选择
  Thickness selection of steel bottom box
  a的埋设深度应在平整层与地面装饰层之间。埋深应小于55mm。应选用超薄钢底箱。
  A the buried depth shall be between the leveling layer and the ground decoration layer. The buried depth shall be less than 55mm. Ultra thin steel bottom box shall be selected.
  B埋深标准嵌钢底箱,地坪加固结构与装饰层之间可选厚度65-75mm。
  B. the buried depth is standard embedded steel bottom box, and the optional thickness between the floor reinforcement structure and the decorative layer is 65-75mm.
  注意事项
  Matters needing attention
  钢箱混凝土浇筑及固定前,需确认钢箱、金属管是否齐全,钢箱有防护罩,防止施工过程中灰尘、杂物掉落。
  Before pouring and fixing the steel box concrete, it is necessary to confirm whether the steel box and metal pipe are complete, and whether the steel box has a protective cover to prevent dust and sundries from falling during construction.
  1. 济南办公室接地插座的安装位置设计及注意事项
  1. Installation position design and precautions of Jinan Office grounding socket
  2. 明确的区域
  2. Clear area
  拆下钢箱底部的防护罩,清理周围的垃圾和安装孔。安装好井盖后,应与地面保持良好接触。
  First remove the protective cover at the bottom of the steel box, clean the surrounding garbage and installation holes. After installing the well cover, keep good contact with the ground.
  3.防腐处理
  3. Anti corrosion treatment
  地板表面装饰材料如大理石、瓷砖、混凝土材料比例不适当,可能会造成风化而不完全干燥,并会引起插座盖的强烈腐蚀。因此,如果周围的混凝土接地孔没有完全干燥,则不应安装此罩。在洞穴附近放置一个或两个防锈漆刷,以覆盖锈蚀的安装盖,避免风化。
  Improper proportion of floor surface decoration materials such as marble, ceramic tile and concrete may cause weathering and incomplete drying and strong corrosion of socket cover. Therefore, this cover should not be installed if the surrounding concrete earth holes are not completely dry. Place one or two anti rust paint brushes near the cave to cover the rusty installation cover and avoid weathering.
  4. 地面
  4. ground
  当安装带有强电源插座的接地插座时,上盖的地线必须与后箱牢固连接。并固定好盖子和低盒。
  When installing the grounding socket with strong power socket, the ground wire of the upper cover must be firmly connected with the rear box. And fix the cover and low box.
  也就是说,这里有一个提示:在决定要打开和关闭的插座数量时,要考虑尽可能多的插座,并设置一个备用插座。更多的插座比不够。
  That is to say, here is a hint: when deciding the number of sockets to open and close, consider as many sockets as possible, and set up a spare one. More sockets than enough.
  今天的精彩内容就暂且给大家介绍到这里了,小编十分感谢大家的认真阅读,如果大家对还有问题想要咨询济南办公室装修的,欢迎大家收藏我们的官网给我们留言:http://www.saiyunzs.com
  Today's wonderful content will be introduced here for the time being. Thank you for reading it carefully. If you want to consult Jinan Office decoration for any questions, please collect our official website and leave us a message: http://www.saiyunzs.com

山东赛郓建筑工程有限公司    流量统计:
地址:山东省济南市历下区保利大明湖
电话:18678802707 
邮箱:1796599844@qq.com