来源:https://www.saiyunzs.com 时间:2018-08-27 16:13:47

一般的民用建筑的楼面负荷是按1.5-2.5kN/㎡设计,即荷载不超过150KG/㎡;如果是悬空的空间,应征求结构设计师的意见,办公空间的间隔好都设在建筑梁的上面;另外一些超重的结构或设施的设置则应由结构重新设计承重或连接结构。

In general, the floor load of civil buildings is designed according to 1.5-2.5 kN/, i.e. the load does not exceed 150 KG/; in case of suspended space, the structural designer should be consulted, and the interval of office space should be built above the building beam; in addition, some overweight structures or facilities should be redesigned by structural experts or load-bearing. Connection structure.
1、消防方面,因涉及种种设备和材料,种种标准和规范,所以应由人士负责。布局方面,在济南办公室装修施工时一般都要经公安消防部门的审批和验收。济南办公室装修时的重新布局又会出现许多新的间隔和通道。
1. Fire safety, because it involves a variety of equipment and materials, a variety of standards and norms, so should be responsible by professionals. In terms of layout, Jinan office decoration and construction generally have to be examined and approved by the public security fire department and acceptance. There will be many new gaps and passages in the re layout of Ji'nan office.
2、在每层建筑平面上,除了有主门以外,还应留有出口,门应为向外开的防火专用门。一些较大的办公室,如50-60㎡,使用人员较多,好能有两个或以上的门口。如只有一个门口,则其宽度应在1.4m以上;超过60㎡的房间或通道长超过14m的房间必须有两个以上的门口;防火规范规定,疏散用的通道小宽度不应小于1.1m。
2. On each floor, besides the main door, there should be a safety exit. The safety door should be a special fire-proof door open to the outside. Some larger offices, such as 50-60, have more staff, preferably with two or more doors. If there is only one doorway, the width should be more than 1.4 m; a room over 60 feet or a room with a passage length of more than 14 m must have more than two doorways; according to the national fire protection code, the minimum width of the passage for evacuation should not be less than 1.1 M.
济南办公室装修
3、用材方面,天花材料如需使用较小面积木质造型,则必须按消防标准涂上防火涂料。天花吊顶允许使用的材料是在金属龙骨上安装石膏板、钙化板、爱特丽版、矿岩板、金属板等;隔墙材料一般不用易燃材料,如易燃塑料、木材等。少量因造型需要的,须在木龙骨和木板内部按消防标准涂防火涂料;装饰壁如有海绵、人造革、织物等装饰,则必须在其表面喷专用防火涂料。
3. In terms of materials, if smallpox materials need to use a small area of wood modeling, they must be coated with fire-proof paint according to fire-fighting standards. Ceiling ceiling allowed to use the safety material is a metal keel on the installation of gypsum board, calcified board, Atlantic plate, ore and rock plate, metal plate, etc., partition materials generally do not use inflammable materials, such as inflammable plastics, wood, etc. A small amount of fire retardant paint should be applied to the inside of keel and board for the purpose of modeling, and special fire retardant paint must be sprayed on the surface of decorative wall if it is decorated with sponge, artificial leather and fabric.
4、电器布线工程应由电器工程师审批签字后,再由正规电工来负责安装施工。电线必须有足够线径来担负连接电器的用电负荷。室内的隐蔽电线,也一定要穿行在密封的金属或难燃塑料管道中。
4. The electrical wiring project shall be examined and signed by the electrical engineer, and then be installed and constructed by the regular electrician. The wire must have enough wire diameter to bear the electrical load for connecting the electrical appliances. Indoor hidden wires must also be worn in sealed metal or non combustible plastic pipes.
5、济南办公室装修中的室内造型应结构牢固,特别是一些吊在空中的装饰。经验表明,贴墙贴柱的石材、作门作窗的玻璃,只要安得不牢固,都可能会在日后突然成为可怕杀手;造型尺度要符合人体功能和使用习惯;一些锐利坚硬的造型,要尽量避开使用者经常活动的空间,避免坚实的台角柜边、外露的柱子、拐弯处的坚硬造型等碰伤行人。
5. The interior modelling of Jinan office decoration should first be firmly structured, especially some hanging in the air. Experience has shown that if the stone stuck to the wall and the glass used for doors and windows is not securely installed, they may suddenly become a terrible killer in the future; the scale of modelling should conform to the human body's functions and usage habits; some sharp and hard modelling should try to avoid the space that users often move, and avoid the solid corner of the counter, exposed. Pillar, the hard shape at the corner hurt the pedestrians.